Contact Us

Contact Us

Dry as molded
Characteristic Unit Test method Measured value
Mechanical property
Tensile strength MPa  ISO 527-1,2 80
Tensile strain at break >50
Tensile modulus MPa 2800
Flexural strength MPa  ISO 178 110
Flexural modulus MPa 2700
Charpy notched impact strength kJ/m2  ISO 179-1/1eA 7
Tensile strength after moisture absorption MPa  ISO 527-1,2 35
Tensile modulus after moisture absorption MPa 800
Tensile strain at break after moisture absorption % >50
Flexural strength after moisture absorption MPa  ISO 178 33
Flexural modulus after moisture absorption MPa 700
Rockwell hardness R.Scale -  ISO 2039 120
M.Scale 80
R.Scale(After Moisture absorption) 93
M.Scale(After Moisture absorption) 35
Thermal property
Melting temperature  ISO 11357 215~225
Temperature of deflection under load 0.45 MPa  ISO 75-1,2 145
1.8 MPa 60
Coefficient of linear thermal expansion x10-5/K  ISO 11359-2 8.0
Electrical property
Dielectric strength kV/mm  IEC 60243-1 20
Arc resistance sec  ASTM D495 118
Comparative Tracking Index -  UL 746A 0
Dielectric constant -  IEC 60250 3.5
Dielectric constant (1 MHz) -  ASTM D150 3.5
Dissipation factor (1 MHz) 20
Other property
Density g/cm3  ISO 1183 1.14
Water absorption equilibrium  UBE method 3.0